Sector Deep Dive · 17 November 2026

The heat now leaves by pipe.

For thirty years a data centre's cooling problem was moving air. AI hardware has changed that. The newest racks are cooled by liquid piped to the chip, and the people who design, build and run that pipework are now some of the most important hires in the hall.

Air has run out of room.

NVIDIA describes its current rack scale AI systems as liquid cooled, with a full rack power density of 120 kW. In the same piece it puts older facilities at about 20 kW per rack. Those are a vendor's figures, but the direction is not in dispute. Air cannot carry that much heat out of that little space at any sensible cost, so the heat has to leave by pipe.

Australian operators are already working this way. In September NEXTDC and Vertiv won the innovation award at the first Data Centres Australia Excellence Awards for a live liquid cooled AI environment inside NEXTDC's S3 Sydney facility, built so customers can test hardware under real operating conditions.

The building becomes a hydronic system.

In a liquid cooled hall, the critical path runs through plant that used to belong to hospitals, laboratories and district energy schemes rather than to IT.

  • Coolant distribution units that separate the facility water from the fluid running through the servers.
  • Secondary fluid networks down every row, with manifolds, quick connects and isolation at each rack.
  • Water treatment, filtration and chemistry, because a blocked cold plate is a failed server.
  • Leak detection and controls that have to talk to both the building management system and the IT load.
  • Heat rejection on the roof, sized for a load that can swing hard with the work the chips are doing.

Most new AI halls will run a hybrid, with air still handling part of the load. That makes the design harder, not easier.

The mechanical engineer moves to the front of the queue.

In our experience, data centre hiring has been led by electrical people for most of the last decade: power, generators, switchgear, connection. Those roles are not going away. What has changed is that the mechanical engineer is now carrying risk that sits right next to the servers.

The profile clients ask us for is narrow. Hydronic design at scale, an understanding of fluid chemistry and materials compatibility, and enough controls knowledge to work through a failure scenario with the IT team. People who have done this inside a live liquid cooled hall are rare in Australia and New Zealand, because there have not been many of those halls until recently.

Commissioning gets wetter, and longer.

A liquid system has to be flushed, filled, pressure tested, cleaned and proven before any customer hardware goes near it. Integrated testing now has to show what happens when a pump fails or a valve sticks with racks at full load, not just when a cooling unit trips.

That changes the commissioning team. Mechanical commissioning managers with hydronic experience, water treatment specialists and controls engineers who can script those tests are all in demand, often on contract and often on the same few campuses at once.

Where to find the people.

Owners and builders. Look past the data centre CV. Hospital and laboratory engineers, district energy and chilled water specialists, pharmaceutical plant people and process engineers from food and beverage all understand clean fluid systems that cannot fail. Pair them with someone who knows the IT side and they come up to speed quickly.

Brief the role on the system, not the title. Say whether it is direct to chip, immersion or a hybrid, who owns the fluid inside the rack, and where the boundary with the IT team sits. Good candidates will ask, and a vague answer loses them.

Candidates. If you have spent your career on hydronic systems in hospitals, labs or process plants, this is a sector that wants to hear from you. Learn the vocabulary of the hall and the move is shorter than it looks.

The servers get the attention. The pipework decides whether they run.